CA-301 ISSUE 1 MAY ‘99
-
2-
SEQUENTIAL TURN ON
Your P-303 is factory set as being the 1
st
amp (AMP 1) to be turned on in sequence. To re-
program your unit so that it would be the 2
nd
, 3
rd
, 4
th
, 5
th
or 6
th
amp to be turned on in sequence you
have to follow this procedure. Push and hold the power button, when the LED becomes solid green,
depress the button and then press again. The number of times you will press again will determine
when the amplifier will turn on in the sequence. See example on the next page.
EX: Push and hold power button until solid green, when power LED is solid green, depress button
and then push 2 times. Then your amplifier will be the 2
nd
one to turn on in the sequence.
The P-303 may also be turned on and off using our SSP-50 Surround Sound Processor, utilising the
IR OUT and IN jacks. Several amplifiers may be turned on automatically in sequence or all at once,
depending upon the configuration of the jumper settings in the amplifier. Please contact your dealer
for set-up specific to IR operation.